Invertor micro, monofazat, 0.2 - 2.2 kW

+ TVA 174,80 EUR + TVA
Rated power:

Rated current: 1,4 A


Cod AC: HIT100001


In stoc

Durata de livrare: 5 zile

Limita stoc
Adauga in cos
Cod Produs: NES1-002SBE Ai nevoie de ajutor? 021 304 62 33
Adauga la Favorite Cere informatii
  • Descriere
  • Caracteristici
  • Download (5)
NE-S1: invertorul entry-level, pretabil pentru aplicaţii comune şi simple
Gama de convertizoare de frecventa monofazate NE-S1 de la Hitachi cu un design-ul ultra-compact reprezintă soluţia economică şi simplă de folosit în aplicații precum: ventilatoare, pompe, mașini de prelucrare a alimentelor.


Principalele avantaje:
  • PID, funcţii integrate logice şi de întârziere de timp
  • interfaţă standard RS-485 Modbus RTU
  • timpi mici de reacţie
  • funcţie standard de economie energie
  • afişaj opţional montat pe partea frontală


Funcțiile seriei Hitachi NE-S1:
- Funcție de economisire a energiei
- Comutare tastatură / terminale
- A doua functie motorie
- Deconectare intrare analogica
- Funcțiile RUN/STOP/RESET integrate într-un singur buton

Number of Phases: 1

Voltage: 200 V

IP protection: IP20

Digital display: Optional

Filter: Optional

Clock/Pulse Frequency Max.: 15kHz

Input Frequency Min.: 50Hz

Input Frequency Max.: 60Hz

Digital Input Type: 5x 24 VDC

Digital Output Type: 1x 24 VDC

Analogue Output Type: 0 ... 10 V

Analogue Input Type: 0 ... 10 V 0/4 ... 20 mA

Relay Output Type: 1x 250 VAC / 30 VDC @ 2.5 A

Interface Type: MODBUS RTU RS485

Mounting Type: DIN Rail Mount

Termination Type: Screw Terminal

Operating Temperature Min.: -10°C

Output Frequency Min.: 0.1Hz

Certification: CE, UL, cUL, c-Tick

Other Functions: AVR (Automatic Voltage Regulation), V/f characteristic selection, accel./decel. curve selection, frequency upper/lower limit, 8 stage multispeed, PID control, frequency jump, external frequency input bias start/end, jogging, trip history etc.

Options: Remote operator with copy function (WOP), Remote operator (OPE-SRmini, OPE-SR), Operator (NES1-OP), input/output reactors, DC reactors, radio noise filters, LCR filter, communication cables (ICS-1, 3)

Protective Functions: Over-current, Over-voltage, Under-voltage, Overload, Overheat, Ground fault at power-on, Input over-voltage, External trip, Memory error, CPU error, USP error, Driver error, Output phase loss protection

Compara produse

Trebuie sa mai adaugi cel putin un produs pentru a compara produse.

A fost adaugat la favorite!

A fost sters din favorite!